Contacts: 1 CO, 1 NO; rated load AC1 – 6 A/250 V AC or 0,05 A/30 V AC; coils DC; for PCB and sockets
| Contact data |
||
| Number and type of contacts |
1 CO, 1 NO |
|
| Max. switching voltage |
(AgSnO2, AgNi) 400 V AC /250 V DC |
|
| Rated load |
(AgSnO2, AgNi) AC1: 6 A /250 V AC; DC1: 6 A /30 V DC; 0,15,A/250 V DC |
|
| Coil data |
||
| Rated voltage DC |
5, 6, 9, 12, 24, 48, 60 V |
|
| Rated power consumption DC |
0,17 W 5 ... 24 V 0,21 W 48,60 V |
|
| General data |
||
| Electrical life resistive AC1 |
the NO and NC contact loaded (bilateral load) |
|
| Electrical life resistive AC1 |
the NO contact loaded >3 x 104 6A, 250 V AC |
|
| Mechanical life (cycles) |
> 107 |
|
| Ambient temperature operating |
-40...+85 oC |
|