Multifunction monitoring relay for 3-phase 3(N)~ 400/230 V networks, with True RMS measurement, rated voltage adjustment, phase loss and phase sequence monitoring.
Technical Data
| Number and type of contacts |
2 CO |
| Max. switching voltage |
250 V |
| Rated load AC1 |
8 A |
| Rated current |
8 A |
| Max. breaking capacity AC1 |
2000 VA |
| Min. breaking capacity |
500 mW |
| Electrical life • resistive AC1 |
1 × 10⁵ |
| Mechanical life (cycles) |
1 × 10⁷ |
| Insulation rated voltage |
500 V |
| Insulation pollution degree |
2 |
| Precision of potentiometer adjustment |
10% |
| Values affecting the timing adjustment • temperature |
0,05%/°C |