PRUCT-M with socket GUC11S - railroad interface relays

Technical info

Zgodne z normami: PN-EN 45545-2 (kategoria EL10, wymaganie R26 - klasa palności V-0 zgodnie z PN-EN 60695-11-10); PN-EN 61373:2011 kategoria 1, klasa B (odporność na udary mechaniczne i wibracje); PN-EN 50155:2007; PN-EN 60077-1; PN-EN 61810-1.

Contact data 

Number and type of contacts

1 NO (double-break), 2 NO

Rated switching voltage 

250 V DC; 250 V AC

Rated load   

DC1: 10 A / 220 V DC;  3,8 A / 220 V DC  

Coil data

Rated voltage

DC: 24, 110 V

Rated power consumption

DC: 1,7 W reinforced version

General data 

Electrical life                     DC1

> 2 x 105 10 A; 220 V DC;  > 2 x 105 3,8 A; 220 V DC  

Mechanical life (cycles) 

> 2 x 107

Ambient temperature  - operating  

 -40...+55 oC

Ask for the details of the offer

I consent to the processing of my personal data by Relpol S.A. More information on the processing of personal data in the Privacy Policy*
I have read the Privacy Policy*