Contacts: 1NO; rated load AC1 – 20 A/250 V AC; coils DC – sensitive; coil terminals PCB, contacts terminals for PCB and flat insert connectors
| Contact data | |
| Number and type of contacts | 1 NO | 
| Rated / max. switching voltage AC | 250 V / 400 V | 
| Rated load (capacity) | AC1: 20 A / 250 V AC; DC1: 20 A / 24 V DC | 
| Coil data | |
| Rated voltage DC | 5, 6, 9, 10, 12, 18, 24, 48 V | 
| Rated power consumption DC | 0,25 W | 
| General data | |
| Electrical life resistive AC1 | >104 20 A, 250 V AC, 85 °C | 
| Electrical life resistive AC1 | >1,5 x 105 10 A, 250 V AC, 105 °C | 
| Mechanical life (cycles) | >3 x 107 | 
| Ambient temperature operating | -40...+105 oC |