Contacts: 2 CO; rated load AC1 – 12 A/250 V AC; coils DC. Mechanical shock and vibration resistance
Zgodne z normami: PN-EN 45545-2 (kategoria EL10, wymaganie R26 - klasa palności V-0 zgodnie z PN-EN 60695-11-10); PN-EN 61373:2011 kategoria 1, klasa B (odporność na udary mechaniczne i wibracje); PN-EN 50155:2007; PN-EN 60077-1; PN-EN 61810-1.
|    Contact data  | 
|
|    Number and type of contacts  | 
   2P  | 
|    Rated switching voltage  | 
   250 V AC  | 
|    Rated load  | 
   AC1: 12 A / 250 V AC; DC1: 12 A / 24 V DC  | 
|    Max. breaking capacity  | 
   AC1: 3 000 VA  | 
|    Coil data  | 
|
|    Rated voltage  | 
   DC: 24, 110 V  | 
|    Rated power consumption  | 
   DC: 0,9 W  | 
|    General data  | 
|
|    Electrical life AC1  | 
   >105 12 A, 250 V AC  | 
|    Mechanical life (cycles)  | 
   >2 x 107  | 
|    Ambient temperature - operating  | 
   -40...+55 oC  |