Contacts: 1CO, 1NO; rated load AC1 – 12 A/250 V AC or 10 A/250 V AC; coils AC, DC, DC – sensitive (1 NO); for PCB and sockets
|    Contact data  | 
|
|    Number and type of contacts  | 
   1 CO, 1 NO  | 
|    Rated / max. switching voltage AC  | 
   250 V / 400 V  | 
|    Rated load (capacity)  | 
   AC1: 12 A / 250 V AC; DC: 12 A / 24 V DC standard versions  | 
|    Coil data  | 
|
|    Rated voltage  | 
   AC 50/60 Hz: 12, 24, 48, 60, 110, 115, 120, 220, 230, 240 V; DC: 3, 5, 6, 9, 12, 18, 24, 36, 48, 60, 110 V standard versions  | 
|    Rated power consumption  | 
   AC: 0,75 VA; DC: 0,4 ... 0,48 W standard versions  | 
|    General data  | 
|
|    Electrical life resistive  | 
   >105 12 A, 250 V AC standard version  | 
|    Mechanical life (cycles)  | 
   >3 x 107  | 
|    Ambient temperature operating  | 
   AC: -40...+70 oC; DC: -40...+85 oC  |