RPC-.MA-... NEW

Technical info

 

RPC-1MA-...

RPC-2MA-...

Number and type of contacts

1 CO

2 CO

Rated load

AC1

16 A / 250 V AC

8 A / 250 V AC

DC1

16 A / 24 V DC

8 A / 24 V DC

DC1

0,3 A / 250 V DC

0,3 A / 250 V DC

Input rated voltage

50/60 Hz AC

230 V         terminals A1, A2

AC: 50/60 Hz AC/DC

12...240 V         terminals (+)A1, (-)A2

Time functions:

  • E    - ON delay
  • Wu - ON for the set interval
  • Bp  - Symmetrical cyclical operation pause first
  • Bi   - Symmetrical cyclical operation pulse first
  • R    - OFF delay with the control contact S
  • Ws - Single shot for the set interval triggered by closing of the control contact S
  • Wa - ON for the set interval triggered with the control contact S
  • Esa - ON and OFF delay with the control contact S
  • B    - Cyclical operation controlled with closing of the control contact S
  • T    - Generation of the 0,5 s pulse after the interval T.

Angielskie wielofunkcyjne

Tables of equivalents of MT-T  - Download